18/12 Shielded Substation Control Cable – 15/10 PE/PVC

$146.00 $582.00

  • Unconditional Satisfaction Guarantee
  • No Shipping Fees Above 30
  • 2 Months to Decide. Returns Simplified.
SKU: CMU727665862001

This 18 AWG, 12-conductor shielded substation control cable is a high-performance utility cable engineered for multi-circuit supervisory control, secondary metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a specialized 15/10 PE/PVC insulation system and a heavy-duty copper tape shield. This construction provides exceptional dielectric strength, a compact profile, and critical protection against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.

Key Features of 18/12 Shielded 15/10 Substation Cable

  • Compact 15/10 Composite Insulation: Each of the 12 conductors is insulated with 15 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection. This thinner insulation profile allows for reduced overall cable diameter and easier routing in high-density terminal blocks.

  • Superior EMI/RFI Shielding: Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a continuous, low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic/electrostatic currents caused by breaker operations and inductive switching.

  • Utility-Grade Durability: Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation pathsapproved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.

  • Corrosion-Resistant Base: Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.

Common Applications

  • Substation Control Networks: Consolidating multiple digital or analog low-current signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.

  • Protective Relaying & Telemetry: Connecting secondary arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.

  • Utility Metering & Monitoring: Long-run multi-point data interconnects, SCADA RTU loops, and power monitoring circuits operating near extra-high-voltage (EHV) busses.

  • Industrial Heavy Duty Control: General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.

Conductor Identification: ICEA E-1 Color Code Sequence

  • Black, White, Red, Green, Orange, Blue, White/Black, Red/Black, Green/Black, Orange/Black, Blue/Black, Black/White

Technical Specifications

  • Conductor Size: 18 AWG

  • Number of Conductors: 12

  • Conductor Material: Bare Soft Annealed Copper (Class B Stranded)

  • Insulation System: 15 mils PE / 10 mils PVC (Total 25 mils per conductor)

  • Shielding: 0.005″ (5 mil) Helical Bare Copper Tape Shield

  • Jacket: Flame-Retardant, Moisture- & Sunlight-Resistant Black PVC

  • Voltage Rating: 600V

  • Temperature Rating: 75C Wet or Dry

  • Compliance Standards: ICEA S-73-532 / NEMA WC 57, ASTM B3 & B8, RoHS Compliant

Technical Note: Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.

CABLE TYPE: 18 AWG / 12-Conductor Shielded Substation Control Cable

DISCLAIMER: The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.